Thermo Scientific™ 450iQ Hydrogen Sulfide and Sulfur Dioxide Gas Analyzer

The Thermo Scientific™ 450iQ Hydrogen Sulfide and Sulfur Dioxide Analyzer uses pulsed fluorescence technology to measure concentrations of Hydrogen Sulfide (H2S) and Sulfur Dioxide (SO2) in ambient air.

Product Overview

Thermo Scientific iQ Series Gas Analyzers provide 24/7 access to analyzer data and are built to evolve over time. The platform is designed to minimize downtime and troubleshooting through a reliable and accurate monitoring solution.

The 450iQ Analyzer delivers continuous measurements of H2S and SO2, using pulsed fluorescence to deliver consistent and precise readings.

Discover the iQ Series Gas Analyzer now with a two-year warranty. 

Key Features

Predictive Diagnostics

Anticipate issues before they arise with enhanced serviceability and plug-and-play components. With 24/7 access to the analyzer’s data, it can reduce troubleshooting time using innovative, interchangeable DMC modules in a highly precise, yet durable solution.

Proactive Communications

Ensure optimal performance with iQ360 and email notifications. When enrolled in the iQ360 service, the instrument communicates directly with the technical support team upon alarm activation. The support team formulates a corrective action plan and sends it to the staff via email. Eliminate unexpected challenges and take charge of operations with the iQ Series Gas Analyzers.

Personal Device Connectivity

Real-time, continuous remote monitoring is now achievable with the iQ companion mobile app. The iQ app facilitates remote oversight of iQ gas analyzers, provides simplified communication options, and offers immediate access to maintenance alerts and product documentation.

Specifications

Source: Thermo Scientific - Chemical Analysis Production Process and Analytics

 
Flow Rate 1 L/min.
Inputs 4 Isolated Voltage Inputs 0 to 10 V, 6 Isolated Analog Voltages Outputs, with 4 Selectable Ranges, 6 Isolated Analog Current Outputs, with 2 Selectable Ranges, 16 Digital Inputs (TTL), 8 Solenoid Driver Outputs, 10 Digital Reed Relay Contact Outputs
Linearity ±1 % full scale <100 ppm
Response Time 80 sec. (10 sec. average time) (manual mode), 150 sec. (60 sec. average time), 320 sec. (300 sec. average time)
Span Drift ±1 % full scale (24 hr.)
Temperature (English) Operating 68 °F to 86 °F
Temperature (Metric) Operating 20 °C to 30 °C
Zero Noise 1.0 ppb (Manual SO2 or Combine Sulfur) 3.0 ppb (Automatic mode SO2 or H2S) (10 sec. averaging time), 0.5 ppb 1.5 ppb (60 sec. averaging time), 0.25 ppb 0.75 ppb (300 sec. averaging time)
Certifications/Compliance CE, TUV-SUD Safety, UKCA
Communication Ports 1 RS-232/485 port
1 RS-485 external accessory port
3 Full speed USB ports (one in front, two in rear)
1 Gigabit ethernet port
Communication Protocols MODBUS, streaming
Depth (English) 23 in.
Depth (Metric) 584 mm
Description 450iQ Hydrogen Sulfide and Sulfur Dioxide Analyzer
Detection Limit 2.0 ppb (Manual SO2 or Combine Sulfur)
6.0 ppb (Automatic mode SO2 or H2S) (10 second averaging time)
1.0 ppb 2.0 ppb (60 second averaging time)
0.5 ppb 1.5 ppb (300 second averaging time)
Electrical Requirements 100 VAC, 115 VAC, 220-240 VAC +/-10% @ 300 W
Height (English) 8.62 in.
Height (Metric) 219 mm
Measurement Range 0 to 10 ppm, 0 to 25 mg/m3; Extended: 0 to 100 ppm, 0 to 250 mg/m3
Precision 1% of reading or 1 ppb (whichever is greater)
Weight (English) 48 lb.
Weight (Metric) 21.8 kg
Width (English) 16.75 in.
Width (Metric) 425 mm
Zero Drift (24 hour) Less than 1 ppb
Unit Size Each

 

Videos

Video Credit: Thermo Scientific - Chemical Analysis Production Process and Analytics

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.