Thermo Scientific™ 146iQ Multi-Gas Calibrator

Thermo Scientific iQ Series Gas Analyzers provide access to analyzer data at any time.

Product Overview

With the Thermo Scientific iQ Series Gas Analyzer, people can access the analyzer's data, day or night. Designed to become more intelligent over time, the iQ Series Gas Analyzers reduce troubleshooting time by providing a tough yet highly accurate solution.

The Thermo Scientific™ 146iQ Multi-Gas Calibrator delivers the same high level of performance when calibrating ambient air and other gas monitoring instruments. The Multi-Gas Calibrator's output is used to calibrate instruments performing zero, precision, Level 1 span checks, audits, and multi-point routines, in accordance with U.S. EPA requirements.

Now backed by a two-year warranty, the iQ Series Gas Analyzer platform offers continuous intelligence through the following key features:

Predictive Diagnostics

Enhanced serviceability and plug-and-play components help resolve issues before they occur. Interchangeable DMC modules provide a robust and precise solution, while 24/7 access to analyzer data minimizes troubleshooting time.

Proactive Communications

Maintain performance with iQ360 and email alerts. When subscribed to iQ360, the instrument automatically notifies the technical support team upon alarm activation. The support team then prepares a corrective plan and sends it via email to designated staff. The iQ Series helps reduce surprises and keep operations running smoothly.

Personal Device Connectivity

The iQ companion mobile app enables real-time, continuous remote monitoring. Users can monitor their analyzers, receive maintenance alerts, access product documentation, and contact support directly through the app.

Specifications

Source: Thermo Scientific - Chemical Analysis Production Process and Analytics

 
Detection Limits 1.5 ppb (60 sec. averaging time)
Flow Rate 0.8 L/min.
Inputs 16 Inputs (TLL), 4 Isolated Voltage Inputs 0 to 10 V
Linearity ±0.25 % full scale
Response Time 20 sec. (10 sec. averaging) (Photometer), <180 sec. (Ozonator Response Time)
Span Drift <1 % full scale (1 month)
Temperature (English) Operating 32 °F to 113 °F
Temperature (Metric) Operating 0 °C to 45 °C
Zero Noise 0.75 ppb RMS (60 sec. averaging time)
Accuracy ±0.8 % of reading +0.2 % of full-scale
Certifications/Compliance CE, TUV-SUD Safety, UKCA
Communication Ports

Serial ports:
1 RS-232/485 port
1 RS-485 external accessory port

Other ports:
3 Full Speed USB ports (one in front, two in rear)
1 Gigabit ethernet port

Communication:
MODBUS, Streaming, Gesytec (Bayern-Hessen)

Depth (English) 24 in.
Depth (Metric) 609 mm
Description 146iQ Multi-Gas Calibrator
Electrical Requirements 100-240 VAC 50/60 Hz, 275 watts
Height (English) 8.72 in.
Height (Metric) 221.48 mm
Outputs 6 Isolated voltages outputs
6 Isolated analog current outputs
Precision 1 ppb
Repeatability of Flow Control ±0.2 % of full scale
Voltage 100/240 V
Weight (English) 43 lb. (with 3 MFCs, Ozonator, and Photometer)
Weight (Metric) 19.5 kg (with 3 MFCs, Ozonator, and Photometer)
Width (English) 16.75 in.
Width (Metric) 425.45 mm
Zero Drift <1.0 ppb (24 hours)
Unit Size Each

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.