Thermo Scientific™ 43iQ Sulfur Dioxide Gas Analyzer

The Thermo Scientific™ 43iQ Series Gas Analyzer provides access to analyzer data at any time.

An iQ Series Gas Analyzer offers real-time access to analyzer data. The iQ Series Gas Analyzers are designed to become more intelligent over time and reduce troubleshooting time by offering a durable yet highly accurate solution.

The Thermo Scientific™ 43iQ Sulfur Dioxide Analyzer uses pulsed fluorescence technology to measure sulfur dioxide (SO2) in ambient air, up to 100 ppm, with consistent performance.

Experience the continuous intelligence of the iQ Series Gas Analyzer, now backed by a two-year warranty. Key features of this next-generation gas analyzer platform include:

Predictive Diagnostics

Resolve issues before they occur using plug-and-play components and improved serviceability. With 24/7 access to analyzer data, troubleshooting time is reduced through the use of innovative, interchangeable DMC modules in a highly precise and robust solution.

Proactive Communications

Maintain optimal performance with iQ360 and email alerts. When iQ360 service is active, the instrument automatically communicates with the technical support team upon alarm activation. The support team then develops a corrective plan and sends it to staff via email.

The iQ Series Gas Analyzers help eliminate surprises and keep operations running smoothly.

Personal Device Connectivity

The iQ companion mobile app enables real-time, continuous remote monitoring. The app provides easy access to iQ gas analyzer data, facilitates communication, and allows instant viewing of maintenance alerts and product documentation.

Specifications

Source: Thermo Scientific - Chemical Analysis Production Process and Analytics

 
Detectable Analytes Sulfur Dioxide
Flow Rate 0.5 L/min.
Inputs 4 Isolated Voltage Inputs 0 to 10 V, 16 Digital Inputs (TTL)
Linearity ±1 % full scale
Response Time 60 sec. (10 sec. average time),
110 sec. (60 sec. average time),
320 sec. (300 sec. average time)
Span Drift ±0.5 % full scale (24 hr.)
Temperature (English) Operating 32 °F to 113 °F
Temperature (Metric) Operating 0 °C to 45 °C
Zero Noise 1.0 ppb RMS (10 sec. averaging time), 0.5 ppb RMS (60 sec. averaging time),0.25 ppb RMS (300 sec. averaging time)
Certifications/Compliance CE, TUV-SUD Safety, US EPA: EQSA-0486-060, UKCA
Communication Ports

Serial ports:
1 RS-232/485 port
1 RS-485 external accessory port

Other ports:
3 Full speed USB ports (one in front, two in rear)
1 Gigabit ethernet port

Communication Protocols MODBUS, streaming
Depth (English) 24 in.
Depth (Metric) 609 mm
Description 43iQ Sulfur Dioxide Analyzer
Detection Limit 2 ppb (10 second averaging time)
1 ppb (60 second averaging time)
0.25 ppb (300 second averaging time)
Electrical Requirements 100-240 VAC 50/60 Hz, 275 Watts
Height (English) 8.72 in.
Height (Metric) 221.48 mm
Interferences (EPA Levels) Less than lower detectable limit except for the following:NO < 3 ppb, M-Xylene < 1 ppb, H2O < 3 % of reading
Measurement Range 0-10 ppm, 0-25 mg/m3;
Extended: 0 to 100 ppm, 0 to 250 mg/m3
Outputs 6 isolated analog voltages outputs, with 4 selectable ranges
6 isolated analog current outputs, with 2 selectable ranges; 8 solenoid driver outputs
10 digital reed relay contact outputs
Precision 1 % of reading or 1 ppb (whichever is greater)
Weight (English) 37.1 lb.
Weight (Metric) 16.8 kg
Width (English) 16.75 in.
Width (Metric) 424.45 mm
Zero Drift <0.5 ppb (24 hour)
Unit Size Each

 

Videos

Video Credit: Thermo Scientific - Chemical Analysis Production Process and Analytics

Video Credit: Thermo Scientific - Chemical Analysis Production Process and Analytics

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.